Title :
Reliability of three-electrode spark gaps for synthetic test circuits
Author :
Arsic, N. ; Osmokrovic, P. ; Vujisic, M. ; Stankovic, K.
Author_Institution :
Faculty of Electrical Engineering, University of Pristina, K. Mitrovica, Serbia
Abstract :
Development of a three-electrode spark gap, intended for use in synthetic circuits, is considered in this paper. Two types of three-electrode gas insulated spark gaps have been tested: one with the third electrode located inside the main electrode, and the other with a separate third electrode. A theoretical model which enables optimal design of the spark gap has been presented.
Keywords :
Breakdown voltage; Building materials; Circuit testing; Copper; Delay; Electrodes; Gas insulation; Spark gaps; Sulfur hexafluoride; Vacuum breakdown;
Conference_Titel :
Pulsed Power Conference, 2007 16th IEEE International
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0913-6
Electronic_ISBN :
978-1-4244-0914-3
DOI :
10.1109/PPPS.2007.4652481