Title :
Characterization of a 500J dense plasma focus for producing soft x-rays
Author :
Bures, B.L. ; Krishnan, M. ; Coleman, P.L. ; Thompson, J.R. ; Champagne, K. ; Wilson, K. ; Bixler, A.
Author_Institution :
Alameda Applied Sciences Corp, 626 Whitney St, San Leandro, CA, USA
Abstract :
The scaling of x-ray output with (stored energy)2 and ∼10ns radiation pulse width of the dense plasma focus make it an interesting source of soft x-ray radiation for lithography, biological imaging, nano imaging or soft x-ray diagnostic calibration. AASC was funded by DTRA to explore soft x-ray diagnostic calibration*. In this follow-on study, we explore an alternative electrode configuration with Ar. The soft x-radiation (≫1 keV) yield, radiation pulse width and debris are characterized for our 500J dense plasma focus over 100’s of pulses fired at 0.2 Hz. The radiation yield is compared with (current)4 scaling. A soft x-ray spectrometer is installed to examine the soft x-ray spectrum.
Keywords :
Calibration; Electrodes; Focusing; Lithography; Optical imaging; Plasma density; Plasma diagnostics; Plasma sources; Plasma x-ray sources; Space vector pulse width modulation;
Conference_Titel :
Pulsed Power Conference, 2007 16th IEEE International
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0913-6
Electronic_ISBN :
978-1-4244-0914-3
DOI :
10.1109/PPPS.2007.4652521