DocumentCode
31288
Title
High-Current CT Calibration Using a Sampling Current Ratio Bridge
Author
Rietveld, Gert ; Jol, L. ; van den Brom, Helko E. ; So, Eddy
Author_Institution
Dutch Nat. Metrol. Inst. (VSL), Delft, Netherlands
Volume
62
Issue
6
fYear
2013
fDate
Jun-13
Firstpage
1693
Lastpage
1698
Abstract
A measurement setup is developed for the accurate ratio measurement of ac current transformers (CTs) for primary currents up to 5 kA. A unique property of the system is the use of high-quality digitizers for sampling of the secondary current signals and step-down transformers with different current ratios. This allows for accurate comparison of CTs even when their nominal ratios are not equal. The calibration results of the key components in the setup show that the sampling current ratio bridge has a ratio uncertainty of better than 2 μA/A in magnitude and 0.8 μrad in phase for CT-under-test current ratios that do not differ by more than a factor of 5 from one of the ratios in the reference CT. The linearity of the bridge for input currents changing between 1% and 120% of nominal input current is better than 4 μA/A in magnitude and 0.5 μrad in phase.
Keywords
bridge instruments; calibration; current transformers; electric current measurement; instrument transformers; AC current transformer; accurate ratio measurement; current transformer calibration; high-quality digitizer; sampling current ratio bridge; Alternating current; current measurement; current ratio; current transformers; digital sampling; phase displacement; phase error; ratio error;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2013.2253975
Filename
6506958
Link To Document