DocumentCode :
31288
Title :
High-Current CT Calibration Using a Sampling Current Ratio Bridge
Author :
Rietveld, Gert ; Jol, L. ; van den Brom, Helko E. ; So, Eddy
Author_Institution :
Dutch Nat. Metrol. Inst. (VSL), Delft, Netherlands
Volume :
62
Issue :
6
fYear :
2013
fDate :
Jun-13
Firstpage :
1693
Lastpage :
1698
Abstract :
A measurement setup is developed for the accurate ratio measurement of ac current transformers (CTs) for primary currents up to 5 kA. A unique property of the system is the use of high-quality digitizers for sampling of the secondary current signals and step-down transformers with different current ratios. This allows for accurate comparison of CTs even when their nominal ratios are not equal. The calibration results of the key components in the setup show that the sampling current ratio bridge has a ratio uncertainty of better than 2 μA/A in magnitude and 0.8 μrad in phase for CT-under-test current ratios that do not differ by more than a factor of 5 from one of the ratios in the reference CT. The linearity of the bridge for input currents changing between 1% and 120% of nominal input current is better than 4 μA/A in magnitude and 0.5 μrad in phase.
Keywords :
bridge instruments; calibration; current transformers; electric current measurement; instrument transformers; AC current transformer; accurate ratio measurement; current transformer calibration; high-quality digitizer; sampling current ratio bridge; Alternating current; current measurement; current ratio; current transformers; digital sampling; phase displacement; phase error; ratio error;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2013.2253975
Filename :
6506958
Link To Document :
بازگشت