DocumentCode :
3132708
Title :
Determining Chlorine Decay Constants in Isfahan Water Transportation Pipeline
Author :
Tashauoei, Hamid Reza ; Khiadani, Mahdi Haji ; Karakani, Farham
Author_Institution :
Center of Res., Isfahan Univ. of Med. Sci., Isfahan, Iran
fYear :
2010
fDate :
18-20 June 2010
Firstpage :
1
Lastpage :
4
Abstract :
Chlorine decay was investigated in Isfahan Water Transportation Line. Bulk chlorine demand was determined using laboratory examinations on samples taken from treatment plant clear well. Besides, the relation between UV-adsorbance and chlorine decay was investigated. Results showed that bulk chlorine decay constant is in range of -0.0031 to -0.0042 hr-1 (mean of -0.0037 hr-1) and also showed that there is significant relation between UV-adsorbance and chlorine decay. Based on results wall chlorine decay had the highest effect on chlorine decay.
Keywords :
chlorine; pipelines; sterilisation (microbiological); water treatment; Cl; Isfahan water transportation pipeline; UV-adsorbance; chlorine decay constants; treatment plant clear well; Contamination; Corrosion; Iron; Manganese; Microorganisms; Pipelines; Transportation; Wastewater; Water pollution; Water resources;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Bioinformatics and Biomedical Engineering (iCBBE), 2010 4th International Conference on
Conference_Location :
Chengdu
ISSN :
2151-7614
Print_ISBN :
978-1-4244-4712-1
Electronic_ISBN :
2151-7614
Type :
conf
DOI :
10.1109/ICBBE.2010.5517025