Title :
Impact of Saturation on Transient Behavior of Interior Permanent Magnet Synchronous Motors
Author :
Najafi, Shahram ; Kar, Narayan C.
Author_Institution :
Windsor Univ., Ont.
Abstract :
Interior permanent magnet synchronous machines have larger ferromagnetic path along the quadrature axis and as a result, the q-axis magnetizing reactance saturates significantly under normal operating conditions. Although, the effective air-gap path length along the direct axis is large, the d-axis magnetizing reactance also saturates up to a certain extent. But in the two-axis (d- and q-axis) frame transient analysis of these machines, usually the impact of the saturation, especially the effect of the d-axis saturation is ignored. So, the aim of this paper is to demonstrate the importance of inclusion both d-and q-axis saturation on the transient behavior of permanent magnet synchronous motors in the case of a bolted three-phase symmetrical short circuit fault
Keywords :
permanent magnet motors; short-circuit currents; synchronous motors; transient analysis; d-axis saturation; ferromagnetic path; interior permanent magnet synchronous motors; q-axis magnetizing reactance; short circuit fault; transient analysis; Damping; Magnetic flux; Permanent magnet motors; Permanent magnets; Saturation magnetization; Shock absorbers; Stator windings; Synchronous motors; Transient analysis; Voltage; Interior permanent magnet synchronous machines; Saturation; Short-circuit currents;
Conference_Titel :
Electrical and Computer Engineering, 2006. CCECE '06. Canadian Conference on
Conference_Location :
Ottawa, Ont.
Print_ISBN :
1-4244-0038-4
Electronic_ISBN :
1-4244-0038-4
DOI :
10.1109/CCECE.2006.277735