  • Abstract
    This paper analyzes the effects of the decoupling of the cross-coupling terms when PI synchronous regulators are used in droop characteristic converter. The PI synchronous regulators are implemented for both voltage and current control. An analysis of the different working modes of the converter are presented. Three sub-modes for the island model, Conventional droop mode, power quality mode and Sync mode are analyzed. One mode for grid connected mode, grid supporting mode is analyzed.
  • Keywords
    PI control; distributed power generation; electric current control; power convertors; power supply quality; voltage control; PI synchronous regulators; Sync mode; cross-coupling terms; current control; droop characteristic control; grid connected mode; grid supporting mode; island model; microgrid converters; power quality mode; voltage control; Control systems; Current control; Distributed control; Filters; Power quality; Pulse width modulation inverters; Regulators; Systems engineering and theory; Transient analysis; Voltage control; Droop characteristic control; PI synchronous regulator; cross-coupling;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2009. ICEMS 2009. International Conference on
  • Conference_Location
    Tokyo
  • Print_ISBN
    978-1-4244-5177-7
  • Electronic_ISBN
    978-4-88686-067-5
  • Type

    conf

  • DOI
    10.1109/ICEMS.2009.5382834
  • Filename
    5382834