DocumentCode :
314095
Title :
Optical refractometry using a monolithically integrated Mach-Zehnder interferometer
Author :
Maisenholder, B. ; Zappe, H.P. ; Kunz, R.E. ; Moser, M. ; Riel, P.
Author_Institution :
Paul Scherrer Inst., Villigen, Switzerland
Volume :
1
fYear :
1997
fDate :
16-19 Jun 1997
Firstpage :
79
Abstract :
Integrated optical sensors, based on evanescent wave sensing, are useful for numerous applications, including medical, environmental and food analysis. System miniaturization is a key issue in their further development. We present the design and fabrication of a novel refractometric transducer, where all optoelectronic components (laser, waveguide, modulators, detectors and sensor pads) are and report on its performance as a refractometer in a flow-through system
Keywords :
Mach-Zehnder interferometers; integrated optics; optical sensors; refractive index; refractive index measurement; design; environmental application; evanescent wave sensing; fabrication; flow-through system; food analysis; integrated optical sensors; medical application; miniaturization; monolithically integrated Mach-Zehnder interferometer; optical refractometry; optoelectronic components; refractometric transducer; Biomedical optical imaging; Biomedical transducers; Integrated optics; Optical design; Optical device fabrication; Optical refraction; Optical sensors; Optical surface waves; Optical waveguides; Waveguide lasers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Solid State Sensors and Actuators, 1997. TRANSDUCERS '97 Chicago., 1997 International Conference on
Conference_Location :
Chicago, IL
Print_ISBN :
0-7803-3829-4
Type :
conf
DOI :
10.1109/SENSOR.1997.613586
Filename :
613586
Link To Document :
بازگشت