Automated daily quality assurance of medical digital x-ray equipment
Author :
Zelikman, Mikhail ; Kruchinin, Sergey
Author_Institution :
Res. & Practical Centre of Med. Radiol., Moscow, Russia
fYear :
2013
fDate :
23-27 June 2013
Firstpage :
1
Lastpage :
4
Abstract :
Quality assurance of the x-ray equipment includes a set of various tests among which are installation and periodic exams performed by qualified engineers as well as daily routine tests carried out by the medical staff of the Radiology Department. As a rule, the decision concerning the applicability of the x-ray equipment for using in clinical studies is made on the basis of the routine tests results. The presented method is based on the detector´s output signals, Signal-to-Noise Ratio and Modulation Transfer Function evaluation in automated way using the simple test-object´s digital image registered with given geometry and x-ray exposure parameters settings. Rectangular 20 mm thick aluminum plate with fixed 1 mm thick well-finished steel edge (for general x-ray radiography/fluoroscopy systems) or 2 mm thick aluminum plate with fixed 1 mm thick aluminum well-finished edge (for digital xray mammography systems) can be used as a test equipment. Relevant to the decision concerning the x-ray device operation status are the parameters: deviations from the reference levels of the tube voltage and mAs as well as internal detector´s noise variance and detector´s gain deviations. Everyday testing procedure includes the following steps. On the first step the roentgenographer places the test-object at the center of the detector´s surface, makes an exposure with specified parameters setting and geometry and after this, test results are displayed on the work station monitor or console screen in automatic way. In order to provide an automated regime of the presenting algorithm, the software must be integrated with the program module intended for the x-ray device control. The use of the presented method in clinical practice provides the reliable daily monitoring of the x-ray equipment operation status prior to its utilizing for patient diagnostic process. As a rule, it will take not more than 3-5 minutes for the roentgenographer to complete the routine test in automated mode.
Keywords :
X-ray apparatus; diagnostic radiography; mammography; optical transfer function; quality assurance; X-ray device control; X-ray device operation; X-ray exposure parameters; X-ray radiography; automated daily quality assurance; clinical studies; detector output signals; digital X-ray mammography; fluoroscopy; gain deviations; geometry; medical digital X-ray equipment; modulation transfer function; noise variance; patient diagnostic process; program module; rectangular aluminum plate; signal-to-noise ratio; steel edge; test-object digital image; tube voltage; Aluminum; Biomedical imaging; Calibration; Electron tubes; Radiography; Testing; X-ray imaging; digital x-ray equipment; quality assurance; routine test; test-object;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2013 3rd International Conference on
Conference_Location :
Marseille
Print_ISBN :
978-1-4799-1046-5
Type :
conf
DOI :
10.1109/ANIMMA.2013.6727892
Filename :
6727892
Link To Document :
بازگشت