DocumentCode :
3145637
Title :
Iron loss estimation method for general hysteresis loop with minor loops
Author :
Taitoda, T. ; Takahashi, Y. ; Fujiwara, K.
Author_Institution :
Doshisha Univ., Kyotanabe, Japan
fYear :
2015
fDate :
11-15 May 2015
Firstpage :
1
Lastpage :
1
Abstract :
In order to design highly-efficient electrical machines, it is necessary to estimate their iron losses accurately. The conventional iron loss estimation method estimates iron loss based on the assumption that eddy current loss coefficient (ke) and hysteresis loss coefficient (kh) under non-sinusoidal excitation are equal to ke and kh under sinusoidal excitation. However, these coefficients are not identical because minor loops are not centered but on ascending and descending major hysteretic curves. In this paper, we verify whether ke under dc-biased excitation is equal to ke under sinusoidal excitation. In addition, the method of analyzing iron loss under non-sinusoidal excitation using dc-biased magnetic properties is proposed.
Keywords :
eddy current losses; magnetic hysteresis; dc-biased excitation; dc-biased magnetic properties; eddy current loss coefficient; electrical machines; hysteresis loss coefficient; iron loss estimation method; nonsinusoidal excitation; sinusoidal excitation; Eddy currents; Estimation; Frequency locked loops; Harmonic analysis; Iron; Magnetic hysteresis; Magnetic properties;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Magnetics Conference (INTERMAG), 2015 IEEE
Conference_Location :
Beijing
Print_ISBN :
978-1-4799-7321-7
Type :
conf
DOI :
10.1109/INTMAG.2015.7157774
Filename :
7157774