DocumentCode
3146728
Title
Analysis of AC permittivity response measured in ionic Glasses: A comparison between iso and non-iso thermal experimental conditions
Author
Henn, F. ; Garcia-Belmonte, G. ; Bisquert, J. ; Devautour-Vinot, S. ; Giuntini, J.C.
Author_Institution
Inst. Charles Gerhardt, Univ. Montpellier 2, Montpellier
fYear
2008
fDate
15-17 Sept. 2008
Abstract
In this paper, a.c. permittivity is measured using various experimental conditions on a test-case oxide glass. Data obtained using metallic contacts or insulating barriers, i.e. 10 mum thin films of PTFE, placed on both sides of the sample, are compared. The influences of the thermal environment, i.e. iso versus non-iso thermal, and of the application of a constant dc electric field, i.e. BIAS, are investigated.
Keywords
aluminosilicate glasses; dielectric losses; ionic conductivity; permittivity; sodium compounds; AC permittivity; Na2O-Al2O3-SiO2; aluminosilicate ionic glass; dielectric losses; ionic conductivity; isothermal conditions; nonisothermal conditions; novocontrol broad band dielectric spectrometer; Conductivity; Dielectric loss measurement; Dielectric losses; Dielectric measurements; Dielectric thin films; Dielectrics and electrical insulation; Glass; Isothermal processes; Loss measurement; Permittivity measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrets, 2008. ISE-13. 13th International Symposium on
Conference_Location
Tokyo
Print_ISBN
978-1-4244-1850-3
Electronic_ISBN
978-1-4244-1851-0
Type
conf
DOI
10.1109/ISE.2008.4814020
Filename
4814020
Link To Document