DocumentCode :
3146926
Title :
Crosstalk effects from a cascaded line with different heights to a transmission line
Author :
Liu, Weikud ; Kami, Yoshio
Author_Institution :
Univ. of Electro-Commun., Tokyo, Japan
fYear :
2002
fDate :
21-24 May 2002
Firstpage :
91
Lastpage :
94
Abstract :
Crosstalk or coupling characteristics between a cascaded line with an abrupt step on the way and a straight transmission line of finite length are discussed comparing measured and calculated results. To analyze the coupling phenomenon, a modified telegrapher\´s equation including the effects of external fields to the lines system is derived. The fields can be obtained by estimating vector potentials of currents in the line and the terminal sections, where the terminals are fabricated like a "via" configuration. A four-port network expression of the voltage and current at each terminal is obtained from solutions of the equation. We have done some experiments to appraise the utility of the theory used here by comparing the transmission characteristics.
Keywords :
crosstalk; electric current; electromagnetic coupling; electromagnetic interference; multiport networks; transmission lines; EMI; cascaded line height; circuit theory; coupling characteristics; crosstalk effects; current vector potentials; electromagnetic interference; external fields; finite length transmission line; four-port network; modified telegrapher´s equation; straight transmission line; transmission characteristics; voltage; Circuits; Crosstalk; Differential equations; Electromagnetic coupling; Electromagnetic interference; Electromagnetic radiation; Switches; Transmission line theory; Transmission lines; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 2002 3rd International Symposium on
Print_ISBN :
0-7803-7277-8
Type :
conf
DOI :
10.1109/ELMAGC.2002.1177371