DocumentCode
3149389
Title
Thermal neutron detection using Si detector and a boron implanted polyethylene converter
Author
Barelaud, B. ; Makovicka, L. ; Dubarry, B. ; Paul, D. ; Decossas, J.L. ; Vareille, J.C.
Author_Institution
Limoges Univ., France
fYear
1991
fDate
9-12 Sep 1991
Firstpage
77
Lastpage
80
Abstract
The development of semiconductor detector technology has led the authors to consider real time dosimetry. The study concerns the thermal neutron detection through (n,α) reaction on boron 10, with recording of secondary particles (α, 7Li) by a PIPS detector (passivated implanted Si detector). The authors compared theoretical estimates with experimental results from irradiations in CEN Cadarache. This results are given as the number of registered pulses per milliSievert per square centimeter
Keywords
dosimetry; elemental semiconductors; neutron detection and measurement; semiconductor counters; silicon; PIPS detector; Si detector; polyethylene converter; real time dosimetry; registered pulses; secondary particles; semiconductor detector technology; thermal neutron detection; Boring; Boron; Chromium; Detectors; Dosimetry; Estimation theory; Laboratories; Neutrons; Polyethylene; Polymers;
fLanguage
English
Publisher
ieee
Conference_Titel
Radiation and its Effects on Devices and Systems, 1991. RADECS 91., First European Conference on
Conference_Location
La Grande-Motte
Print_ISBN
0-7803-0208-7
Type
conf
DOI
10.1109/RADECS.1991.213604
Filename
213604
Link To Document