DocumentCode :
3160751
Title :
Measurement on narrow band power line communication channel impedance of distribution network
Author :
Tian, Haiting ; Yuan, Ruiming ; Li, Feng ; Huang, Zhigang ; Wang, Sitong ; Li, Shunxin ; Zhong, Kan
Author_Institution :
North China Grid Co. Ltd., Beijing, China
fYear :
2011
fDate :
16-18 April 2011
Firstpage :
454
Lastpage :
457
Abstract :
Impedance of low voltage power line have important effect on performance of power line communication. This paper presents measurements and analysis of the impedance of several electric loads and communication nodes on low voltage residential distribution network at frequencies from 80kHz to 500kHz. These measurement results are valuable and provide important reference on power line communication architecture design.
Keywords :
carrier transmission on power lines; distribution networks; electric impedance measurement; frequency 80 kHz to 500 kHz; impedance measurement; low voltage residential distribution network; narrow band power line communication channel impedance; Frequency measurement; Impedance; Impedance measurement; Power line communications; Power measurement; Transmission line measurements; Distribution network; Impedance; Power line;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference on
Conference_Location :
XianNing
Print_ISBN :
978-1-61284-458-9
Type :
conf
DOI :
10.1109/CECNET.2011.5768876
Filename :
5768876
Link To Document :