DocumentCode :
3160824
Title :
New power factor correction and current harmonic mitigation for AC variable reluctance generator with DC excitation
Author :
Tsukerman, Dimitry ; Rabinovici, Raul
Author_Institution :
Dept. of Electr. & Comput. Eng., Ben-Gurion Univ. of the Negev, Beer-Sheva, Israel
fYear :
2002
fDate :
1 Dec. 2002
Firstpage :
156
Lastpage :
158
Abstract :
The present paper proposes a new approach to compensate the inductive voltage drop on the internal inductance of the AC variable reluctance generator with DC excitation (AVARGED) and also to compensate the higher voltage harmonics produced in it. As a result, the output current and the associated output voltage on a resistive load are sinusoidal waves in phase with fundamental harmonic of the electro-motive force and without any higher harmonics.
Keywords :
exciters; harmonic distortion; harmonics suppression; machine theory; power conversion harmonics; power factor correction; reluctance generators; AC variable reluctance generator; DC excitation; current harmonic mitigation; electro-motive force; higher voltage harmonics compensation; inductive voltage drop compensation; power factor correction; resistive load; sinusoidal output current; sinusoidal output voltage; AC generators; Coils; Equations; Inductance; Power factor correction; Power system harmonics; Reluctance generators; Rotors; Stators; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Electronics Engineers in Israel, 2002. The 22nd Convention of
Print_ISBN :
0-7803-7693-5
Type :
conf
DOI :
10.1109/EEEI.2002.1178375
Filename :
1178375
Link To Document :
بازگشت