Title :
Study about an influence of impedance element for dynamic characteristics measurement with oscillatory gas flow generator
Author :
Funaki, Tatsuya ; Kawashima, Kimiko ; Kagawa, Toshiharu
Author_Institution :
Nat. Metrol. Inst. of Japan, AIST, Tsukuba
Abstract :
In this paper, at first, we consider the tested flow meter as the impedance element including the connected pipe and evaluate the impedance characteristic. And we try to examine the performance of the oscillatory gas flow generator experimentally including the measurement set up condition of the connected pipe and the tested flow meters. Moreover, we will examine the policy how the dynamic characteristic measurement of the tested flow meter is possible in the same condition and will clarify the compensation methods.
Keywords :
flow measurement; flowmeters; fluid oscillations; pipe flow; compensation methods; dynamic characteristics measurement; flow meters; impedance element; oscillatory gas flow generator; Character generation; Cutoff frequency; Fluid flow; Fluid flow measurement; Frequency conversion; Impedance measurement; Isothermal processes; Temperature; Testing; Valves; Flow control; Flow rate measurement; Isothermal chamber; Oscillatory flow; Unsteady flow;
Conference_Titel :
SICE Annual Conference, 2008
Conference_Location :
Tokyo
Print_ISBN :
978-4-907764-30-2
Electronic_ISBN :
978-4-907764-29-6
DOI :
10.1109/SICE.2008.4655179