Title :
Testing to assure reliable operation of electric motors
Author_Institution :
Baker Instrum. Co., Fort Collins, CO, USA
Abstract :
A discussion is presented of several field test procedures that can be used as part of a motor maintenance program. An outline is also presented of failure mechanisms in motor insulation systems. The application of surge comparison testing is discussed along with an interpretation of test results. Since turn-to-turn shorting is a major factor in causing motor winding failure, a test for impaired turn insulation is a good periodic test for motors
Keywords :
electric motors; machine insulation; machine testing; machine windings; reliability; electric motors; failure mechanisms; field test procedures; impaired turn insulation; insulation systems; maintenance program; reliability; surge comparison testing; turn-to-turn shorting; winding failure; Electric motors; Failure analysis; Inductors; Insulation; Maintenance; Polymers; Temperature; Testing; Thermal stresses; Wounds;
Conference_Titel :
Petroleum and Chemical Industry Conference, 1990. Record of Conference Papers., Industry Applications Society 37th Annual
Conference_Location :
Houston, TX
DOI :