DocumentCode :
3162895
Title :
Prediction of flashover voltage based on leakage current under AC operating voltage
Author :
Mei, Hongwei ; Wang, Liming ; Mao, Yingke ; Guan, Zhicheng
Author_Institution :
Grad. Sch. at Shenzhen, Tsinghua Univ., Shenzhen, China
fYear :
2010
fDate :
11-14 Oct. 2010
Firstpage :
329
Lastpage :
332
Abstract :
In this paper, a model to predict the AC flashover voltage of contaminated suspension insulators was presented. The prediction method is based on the maximum leakage current under AC operating voltage. Three kinds of widely used suspension insulators were tested in various contamination statuses such as pollution layers with different ESDD, different composition of the conductive components, different NSDD and different pollution distribution statuses to simulate the contamination statuses in nature. Effective ESDD was proposed and calculated. Influences of contamination statuses to maximum leakage current and flashover voltage were studied. Then, the relationships between flashover voltage and leakage current in these statuses are presented. Finally, considering the difference of insulator profiles, a new parameter is defined and a model to estimate the flashover voltage based on this parameter is developed. The model could be used to all kinds of suspension insulators in different contamination statuses and was validated by the test results.
Keywords :
flashover; insulator contamination; AC flashover voltage prediction; AC operating voltage; ESDD; NSDD; contaminated suspension insulators; equivalent salt deposit density; maximum leakage current; pollution distribution; Flashover; Insulators; Leakage current; Pollution; Surface contamination; Surface fitting;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
High Voltage Engineering and Application (ICHVE), 2010 International Conference on
Conference_Location :
New Orleans, LA
Print_ISBN :
978-1-4244-8283-2
Type :
conf
DOI :
10.1109/ICHVE.2010.5640761
Filename :
5640761