• DocumentCode
    3164250
  • Title

    Quality control of extruded HVDC cables: Low frequency endurance testing of model cables with contaminations

  • Author

    Mauseth, Frank ; Ildstad, Erling ; Selsjord, Mildrid ; Hegerberg, Rolf

  • Author_Institution
    Dept. of Electr. Power Eng., NTNU, Trondheim, Norway
  • fYear
    2010
  • fDate
    11-14 Oct. 2010
  • Firstpage
    136
  • Lastpage
    139
  • Abstract
    This paper presents results from laboratory experiments preformed in order to evaluate different methods for quality assurance of polymeric insulated HVDC cables. Samples of model cables were prepared, equipped with 1.5 mm thick XLPE insulation, containing insulating and conductive spherically shaped particle inclusions with diameters of 250, 140 or 80 μm, distributed at the inner semi-conductor interface. The results indicates that the 0.1 Hz VLF test voltage needs to be 2 to 3 times higher than at 50 Hz power frequency in order to eliminate the same defects within a comparable time.
  • Keywords
    HVDC power transmission; XLPE insulation; power cable insulation; quality assurance; quality control; VLF test voltage; XLPE insulation; conductive spherically shaped particle inclusion; extruded HVDC cable; model cable contamination; polymeric insulated HVDC cable; quality assurance; quality control; semiconductor interface; size 1.5 mm; Breakdown voltage; Electric breakdown; HVDC transmission; Insulation; Mechanical cables; Testing; Time frequency analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    High Voltage Engineering and Application (ICHVE), 2010 International Conference on
  • Conference_Location
    New Orleans, LA
  • Print_ISBN
    978-1-4244-8283-2
  • Type

    conf

  • DOI
    10.1109/ICHVE.2010.5640845
  • Filename
    5640845