• DocumentCode
    3165345
  • Title

    Scheme analysis of capacity-increasing transformation for reheaters of 300MW boilers in a power plant

  • Author

    Jingjing Wang ; Zhenning Zhao ; Liwei Xu ; Wanye Yao

  • Author_Institution
    North China Electr. Power Res. Inst. Co., Ltd., Beijing, China
  • Volume
    3
  • fYear
    2014
  • fDate
    19-21 Aug. 2014
  • Firstpage
    698
  • Lastpage
    702
  • Abstract
    The steam temperature at the outlet of the reheater has always been lower than the designed value in a power plant. A reheat steam temperature adjustment test was conducted on the two subcritical, intermediate reheat and natural circulation boilers in the power plant. By analyzing the test data, reasons of the low reheat steam temperature have been discovered. What´s more, three schemes about capacity-increasing transformation for reheaters have been proposed and compared, after which the most reasonable one is selected. What is studied in the paper provides helpful experiences in solving similar problems for boilers of the same type.
  • Keywords
    boilers; heating; power plants; steam power stations; capacity-increasing transformation scheme analysis; intermediate reheat boiler; natural circulation boiler; power 300 MW; power plant; reheat steam temperature adjustment test; reheater; subcritical boiler; Absorption; Boilers; Electron tubes; Furnaces; Temperature distribution; Turbines; 300MW boilers; capacity-increasing transformation; reheat steam temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Materials for Renewable Energy and Environment (ICMREE), 2013 International Conference on
  • Conference_Location
    Chengdu
  • Print_ISBN
    978-1-4799-3335-8
  • Type

    conf

  • DOI
    10.1109/ICMREE.2013.6893773
  • Filename
    6893773