DocumentCode :
3166547
Title :
Study on controlled by beds combination structure to deep of mining failure of coal seam floor
Author :
Jiwen, Wu
Author_Institution :
Sch. of Resources & Environ. Eng., Anhui Univ. of Sci. & Technol., Huainan, China
fYear :
2011
fDate :
16-18 April 2011
Firstpage :
2641
Lastpage :
2644
Abstract :
The probing method of breakage depth mined are Introduced, and the geology, hydrology and rock strata structure of the coal seam floor mined in the test work face are analyzed. the worth of the breakage depth mined of the 6 coal seam floor in the No.2 coal mine of Liu qiao and Zhu zhuang coal mine are acquired. The results show that the probing method of floor breakage depth is different, but its regularity is similar, and the floor breakage depth is clearly controlled by floor rock strata structure.
Keywords :
coal; failure analysis; fracture; geology; geotechnical engineering; hydrology; mining; rocks; Liu qiao coal mine; Zhu zhuang coal mine; bed combination structure; coal seam floor mining; floor breakage depth; geology; hydrology; mining failure; probing method; rock strata structure; test work face; Coal; Coal mining; Computed tomography; Face; Floors; Rocks; breakage depth mined; coal seam floor; rock strata structure; structure control;