• DocumentCode
    3168890
  • Title

    Source stirring reverberation chamber design and experimental investigation

  • Author

    Liang Shuang-gang ; Wang Zhi-jie ; Xu Jia-dong

  • Author_Institution
    Sch. of Electron. & Inf., Northwestern Polytech. Univ., Xi´an, China
  • fYear
    2009
  • fDate
    7-10 Dec. 2009
  • Firstpage
    1254
  • Lastpage
    1257
  • Abstract
    According to the source stirring reverberation chamber (SSRC) theory, the key factors influencing its performance is analyzed and a source stirring scheme is proposed. Through the experiment, the valuable data for SSRC design and performance evaluation is provided. In the 800 MHz-1000 MHz frequency range, with the smallest sample number of the request, a better field uniformity is obtained. Meanwhile, the statistical characteristics of the electric field magnitude obeys Rayleigh distribution, which performed by the Kolmogorov - Smirnov (K-S) fitting method.
  • Keywords
    Rayleigh scattering; reverberation chambers; statistical distributions; Kolmogorov-Smirnov fitting method; Rayleigh distribution; electric field magnitude; frequency 800 MHz to 1000 MHz; source stirring reverberation chamber design; Boundary conditions; Current distribution; Design engineering; Green´s function methods; Information analysis; Integral equations; Performance analysis; Reverberation chamber; Testing; Tuners; Field uniformity; Reverberation Chamber; Source stirring; statistical characteristics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 2009. APMC 2009. Asia Pacific
  • Conference_Location
    Singapore
  • Print_ISBN
    978-1-4244-2801-4
  • Electronic_ISBN
    978-1-4244-2802-1
  • Type

    conf

  • DOI
    10.1109/APMC.2009.5384443
  • Filename
    5384443