• DocumentCode
    3169042
  • Title

    Study on influencing factors of thermal performance of the flat-plate solar air collector

  • Author

    Xu, Shuhui ; You, Jun ; Dong, Haiguang ; Li, Wenfang

  • Author_Institution
    Sch. of Environ. & Energy Eng., Beijing Univ. of Civil Eng. & Archit., Beijing, China
  • fYear
    2011
  • fDate
    16-18 April 2011
  • Firstpage
    3584
  • Lastpage
    3587
  • Abstract
    A 3-D numerical model of the flat-plate solar air collector was established. Five influencing factors of collector efficiency were selected and discussed. The Simulation program with orthogonal experiments was designed. With FLUENT simulation results, five factors that influence the collector efficiency are analyzed. Solar radiation intensity is a main factor that influences the collector efficiency. When the collector inlet air temperature is 283.15K, collector efficiency ranged from 64% to 80% with different working conditions designed by orthogonal experiment. Also, six to one of the best aspect ratio of the collector is verified.
  • Keywords
    numerical analysis; solar absorber-convertors; sunlight; 3D numerical model; FLUENT simulation; efficiency 64 percent to 80 percent; flat-plate solar air collector; simulation program; solar radiation intensity; temperature 283.15 K; thermal performance; Atmospheric modeling; Employee welfare; Renewable energy resources; Simulation; Solar heating; Solar radiation; Tin; collector efficiency; flat-plate solar air collector; influencing factors; orthogonal experimental design;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference on
  • Conference_Location
    XianNing
  • Print_ISBN
    978-1-61284-458-9
  • Type

    conf

  • DOI
    10.1109/CECNET.2011.5769303
  • Filename
    5769303