High-power pulsewidth controlled current source GTO inverter for high switching frequency
Author
Holtz, J. ; Stamm, M. ; Thur, J. ; Linder, A.
Author_Institution
Wuppertal Univ., Germany
Volume
2
fYear
1997
fDate
5-9 Oct 1997
Firstpage
1330
Abstract
High-power GTO inverters require regenerative snubbers to ensure operation at predefined values of di/dt and du/dt. The use of regenerative snubbers for voltage source inverters is a well established technology. However, the proliferation of high-power PWM current source inverters is impeded by the nonavailability of an appropriate regenerative snubber scheme. The paper proposes a regenerative snubber for current source GTO inverters and reports experimental results of a 1.2 MVA prototype inverter. Energy recovery from the snubbers enables operation at extreme high switching frequency of 1 kHz and reduces the total filter kVA from 70% to 20% of the inverter power
Keywords
DC-AC power convertors; PWM invertors; snubbers; switching circuits; thyristor convertors; 1 kHz; 1.2 MVA; PWM CSI; current source GTO inverter; regenerative snubbers; switching frequency; Capacitors; Circuits; Pulse inverters; Pulse modulation; Pulse width modulation converters; Pulse width modulation inverters; Snubbers; Switches; Switching frequency; Voltage;