DocumentCode :
3169890
Title :
Synchronization of timing systems on TFTR
Author :
Montague, J. ; Sichta, P.
Author_Institution :
Princeton Plasma Phys. Lab., NJ, USA
fYear :
1991
fDate :
30 Sep-3 Oct 1991
Firstpage :
810
Abstract :
The Tokamak Fusion Test Reactor (TFTR) facility clock system has four related timing subsystems: the TFTR shot clock, the neutral beams clocks, the ion cyclotron range of frequencies (ICRF) system clock, and the disruption trigger system. These systems have been integrated to support increasingly fast sampling rates in data acquisition and greater accuracy in the firing of the neutral beams and ICRF systems during TFTR shots
Keywords :
Tokamak devices; fusion reactor instrumentation; fusion reactor theory and design; timing circuits; ICRF; TFTR shot clock; Tokamak Fusion Test Reactor; data acquisition; disruption trigger system; neutral beams clocks; sampling rates; system clock; timing subsystems; Clocks; Cyclotrons; Data acquisition; Frequency synchronization; Inductors; Ion beams; Sampling methods; System testing; Timing; Tokamaks;