DocumentCode :
3170941
Title :
Analysis on stress loss in prestressed concrete structure
Author :
Hu, Weixun
Author_Institution :
Central South Univ. of Forestry & Technol., Changsha, China
fYear :
2011
fDate :
16-18 April 2011
Firstpage :
1075
Lastpage :
1078
Abstract :
This paper aims at the problem of prestress loss caused by friction between prestressed tendon and curved duct for the design of prestressed concrete structure. Formulas of normal pressure between prestressed tendon and curved duct and tension of prestressed tendon are derived based on the Hertz contact theory. And also the results come from experiments, derived formulas and current norms are compared in three cases.
Keywords :
concrete; ducts; stress analysis; structural engineering; Hertz contact theory; curved duct; prestressed concrete structure; prestressed tendon; stress loss; Concrete; Ducts; Force; Friction; Stress; Tendons; Torque; Prestress loss; prestressed concrete structure; prestressed tendon;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference on
Conference_Location :
XianNing
Print_ISBN :
978-1-61284-458-9
Type :
conf
DOI :
10.1109/CECNET.2011.5769397
Filename :
5769397
Link To Document :
بازگشت