DocumentCode
3171924
Title
Visualization of LV wall motion and thickness from MRI data
Author
Johnstone, JK ; Sloan, KR
Author_Institution
Alabama Univ., Birmingham, AL, USA
fYear
1995
fDate
10-13 Sept. 1995
Firstpage
249
Lastpage
252
Abstract
The authors present a tool for visualizing the wall motion and thickness of the left ventricle. Smooth surface reconstructions of the endocardial and epicardial surfaces are computed from MRI slice data, and used to compute wall thickness along the endocardial surface. The endocardial surface is then displayed color-coded by wall thickness. Wall motion can also be visualized as the endocardial surface is drawn beating in real time. The authors believe that this is an intuitive interface for the study of ventricular function and treatment planning.
Keywords
biomechanics; biomedical NMR; cardiology; image reconstruction; medical image processing; motion estimation; thickness measurement; MRI slice data; color-coded display; endocardial surface; intuitive interface; left ventricle thickness; left ventricle wall motion; magnetic resonance imaging; medical diagnostic imaging; treatment planning; ventricular function; Computer interfaces; Data visualization; Fluid flow measurement; Magnetic resonance imaging; Robustness; Shape; Surface reconstruction; Surface treatment; Tensile stress; Thickness measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Computers in Cardiology 1995
Conference_Location
Vienna, Austria
Print_ISBN
0-7803-3053-6
Type
conf
DOI
10.1109/CIC.1995.482619
Filename
482619
Link To Document