DocumentCode
3174917
Title
A system for the detection of ischemic episodes in ambulatory ECG
Author
Taddei, A. ; Costantino, G. ; Silipo, R. ; Emdin, M. ; Marchesi, C.
Author_Institution
Inst. of Clinical Physiol., CNR, Pisa, Italy
fYear
1995
fDate
10-13 Sept. 1995
Firstpage
705
Lastpage
708
Abstract
Describes a system for the automated detection of ischemic changes in double channel ambulatory EGG. The high performance QRS detector, previously designed and tested by the authors, was applied. A subset of ECG records of the European ST-T Database was used for development, whereas the full set of 90 records and selected 24-hour ECG recordings were used for evaluation. Noisy ECG segments were rejected by the QRS detector or processed by the use of median filters. ST segment deviations, measured beat by beat on both channels, were used for detection of ischemic episodes. The time series of parameters were smoothed by nonlinear filters. Episode detection is based on the analysis of the 2-D path of the two ST deviations. Results of performance evaluation on the European ST-T Database are reported.
Keywords
electrocardiography; medical information systems; medical signal processing; patient monitoring; signal sampling; smoothing methods; time series; 2-D path; 24 hour; 24-hour ECG recordings; European ST-T Database; ST deviations; ST segment deviations; ambulatory ECG; automated detection; beat by beat; double channel ambulatory EGG; high performance QRS detector; ischemic changes; ischemic episode detection; median filters; noisy ECG segments; nonlinear filters; time series; Databases; Detectors; Electrocardiography; Ischemic pain; Myocardium; Noise measurement; Nonlinear filters; Phase noise; Signal analysis; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Computers in Cardiology 1995
Conference_Location
Vienna, Austria
Print_ISBN
0-7803-3053-6
Type
conf
DOI
10.1109/CIC.1995.482762
Filename
482762
Link To Document