Title :
Simulated ST segment potentials generated in single and multivessel coronary artery disease
Author :
Hyttinen, J.A. ; Viik, J.J. ; Malmivuo, J.A.
Author_Institution :
Ragnar Granit Inst., Tampere Univ. of Technol., Finland
Abstract :
An accurate computer thorax model was devised to obtain ST segment body surface potentials and 12-lead ECG generated by regionally localized myocardial ischemia. The capability of the leads to detect the location and area of ischemia was appraised. The results agree with clinical knowledge of ischemia detection; limb lead I indicated lateral sources and leads V4 and V5 were generally the best in indicating the sources by ST depression. The 1 mm ST depression criteria was suitable for leads V4 and V5, other leads may need different criteria. ST segment deviation was not directly related to the extent of ischemia or area of the boundary between the healthy and ischemic myocardium.
Keywords :
digital simulation; electrocardiography; physiological models; 12-lead ECG; ST segment body surface potentials; ST segment deviation; accurate computer thorax model; clinical knowledge; healthy myocardium; ischemia detection; ischemic myocardium; lead V4; lead V5; limb lead I; multivessel coronary artery disease; simulated ST segment potentials; single vessel coronary artery disease; Coronary arteriosclerosis; Electrocardiography; Equations; Finite difference methods; Heart; Injuries; Ischemic pain; Myocardium; Solids; Thorax;
Conference_Titel :
Computers in Cardiology 1995
Conference_Location :
Vienna, Austria
Print_ISBN :
0-7803-3053-6
DOI :
10.1109/CIC.1995.482765