• DocumentCode
    3177047
  • Title

    Accurate calibration of cameras and range imaging sensor: the NPBS method

  • Author

    Champleboux, G. ; Lavallée, S. ; Sautot, P. ; Cinquin, P.

  • Author_Institution
    TIMB-IMAG, Fac. de Medecine de Grenoble, La Tronche, France
  • fYear
    1992
  • fDate
    12-14 May 1992
  • Firstpage
    1552
  • Abstract
    A method is presented for modeling and calibration of sensors, to reach an accuracy similar in magnitude to the resolution of the sensors. The authors focus on camera and range image calibration. They show the limitations of existing methods, and present an approach and camera calibration using mathematical B-Spline functions. This method is abbreviated as NPBS (N-Planes B-Spline). It is an extension of the two-planes method, but relies on pure mathematical modeling based on spline approximation theory. The mathematical modeling is combined with a calibration device that enables accurate data acquisition to calibrate a camera and a light plane independently. Experimental results are presented showing accuracy on the determination of a scattered plane
  • Keywords
    approximation theory; calibration; cameras; data acquisition; image sensors; splines (mathematics); N-Planes B-Splines method; accuracy; calibration; cameras; data acquisition; range imaging sensor; resolution; scattered plane; spline approximation; Application software; Biomedical imaging; Calibration; Cameras; Image sensors; Mathematical model; Radiography; Robot kinematics; Robot vision systems; Spline;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Robotics and Automation, 1992. Proceedings., 1992 IEEE International Conference on
  • Conference_Location
    Nice
  • Print_ISBN
    0-8186-2720-4
  • Type

    conf

  • DOI
    10.1109/ROBOT.1992.220031
  • Filename
    220031