• DocumentCode
    3180190
  • Title

    Control volume based thermodynamic modeling applied to the thermal management of a notional all-electric ship

  • Author

    Souza, J.A. ; Ordonez, J.C. ; Vargas, J.V.C. ; Hovsapian, R.

  • Author_Institution
    Dept. of Mech. Eng., Center for Adv. Power Syst., Tallahassee, FL, USA
  • fYear
    2011
  • fDate
    10-13 April 2011
  • Firstpage
    161
  • Lastpage
    166
  • Abstract
    This paper describes an effort to couple a network based simulation of a ship cooling system with a volume element method solver used to compute the temperature distribution within a ship. A notional five zone electric ship configuration is used to illustrate the methodology. Major loads include a radar, turbine generators and a pulse load. A geographic position for each equipment is defined inside the ship geometry. Each zone has a closed fresh water circuit that can be solved independently. Results include water temperature at different locations in the cooling network and spatial temperature distribution inside the hull. The maximum temperature calculated inside the ship dropped from ~700K in the no-cooling scenario to ~320K when the cooling was active.
  • Keywords
    power system simulation; ships; space cooling; temperature distribution; thermodynamics; closed fresh water circuit; control volume; cooling network; five zone electric ship configuration; geographic position; no-cooling scenario; notional all-electric ship; pulse load; radar; ship cooling system; ship geometry; spatial temperature distribution; thermal management; thermodynamic modeling; turbine generators; volume element method solver; water temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Ship Technologies Symposium (ESTS), 2011 IEEE
  • Conference_Location
    Alexandria, VA
  • Print_ISBN
    978-1-4244-9272-5
  • Type

    conf

  • DOI
    10.1109/ESTS.2011.5770860
  • Filename
    5770860