Title :
Magnetic Priming of a Relativistic Magnetron by Ferromagnetic Wires in the Anode and Cathode*
Author :
Gilgenbach, R.M. ; Hoff, B.W. ; Lau, Y.Y. ; Jordan, N.M. ; White, W. ; Zier, J.C. ; Gomez, M.R. ; Cruz, E. ; Spencer, T.A. ; Price, D.
Author_Institution :
Univ. of Michigan, Ann Arbor
Abstract :
Magnetic priming consists of N/2 azimuthal perturbations applied to the axial magnetic field in an N-cavity magnetron. When employed on the UM/L-3-Titan, 6-cavity, relativistic magnetron (L-band, -300 kV, ~3 kGauss), magnetic priming has shown enhanced performance over uniform-B- field operation. Magnetic perturbations are imposed utilizing Mu-metal wires embedded in either the cathode or both the cathode and anode of the magnetron.
Keywords :
anodes; cathodes; ferromagnetic materials; magnetic fields; magnetrons; wires; Mu-metal wires; UM/L-3-Titan; anode; axial magnetic field; azimuthal perturbations; cathode; cavity magnetron; ferromagnetic wires; magnetic perturbations; magnetic priming; relativistic magnetron; Anodes; Cathodes; Frequency; Magnetic fields; Magnetostatics; Microwave communication; Nuclear and plasma sciences; Power engineering and energy; Steel; Wires;
Conference_Titel :
Vacuum Electronics Conference, 2007. IVEC '07. IEEE International
Conference_Location :
Kitakyushu
Print_ISBN :
1-4244-0633-1
DOI :
10.1109/IVELEC.2007.4283397