DocumentCode :
3180838
Title :
The surge analysis of induction heating power supply with PLL
Author :
Chen, Mu-Ping ; Chen, Jan-Ku ; Chen, Shih-Hsin ; Murata, Kentaro ; Nakahara, Masatoshi ; Harada, Koosuke
Author_Institution :
Ind. Technol. Res. Inst., Hsinchu, Taiwan
Volume :
1
fYear :
1999
fDate :
1999
Firstpage :
303
Abstract :
This paper presents the mechanism of surges with induction heating power supply. A 2 kW full-bridge series resonant inverter based on zero-voltage-switching (ZVS) and phase-locked-loop (PLL) control is used as a power supply. In this inverter, the PLL does not only keep the output current and voltage in phase but also manage the system to operate at ZVS mode. When the PLL mismatches the resonant frequency in a manner of phase lead, the inverter works at the nonZVS mode and the surge voltage appears on the switching elements heavily, which is almost decided by the recovery energy of drain-source diode of power devices. The surge model found in this paper is very useful
Keywords :
DC-AC power convertors; bridge circuits; induction heating; invertors; phase locked loops; power supplies to apparatus; resonant power convertors; surges; switching circuits; 2 kW; PLL; ZVS; drain-source diode; full-bridge series resonant inverter; induction heating power supply; output current; output voltage; phase-locked-loop control; surge analysis; switching elements; zero-voltage-switching; Conducting materials; Magnetic materials; Phase locked loops; Power supplies; RLC circuits; Resonant frequency; Resonant inverters; Surges; Voltage control; Zero voltage switching;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Drive Systems, 1999. PEDS '99. Proceedings of the IEEE 1999 International Conference on
Print_ISBN :
0-7803-5769-8
Type :
conf
DOI :
10.1109/PEDS.1999.794579
Filename :
794579
Link To Document :
بازگشت