• DocumentCode
    3182466
  • Title

    A model-based control protocol for transition from ICU to HDU: Robustness analysis

  • Author

    Razak, Normy N. ; Chase, J. Geoffrey ; Suhaimi, Fatanah M. ; Shaw, Geoffrey M. ; Jamaluddin, Ummu

  • Author_Institution
    Univ. Tenaga Nasional, Kajang, Malaysia
  • fYear
    2013
  • fDate
    3-7 July 2013
  • Firstpage
    205
  • Lastpage
    208
  • Abstract
    The robustness of a model-based control protocol as a less intensive TGC protocol using insulin Glargine for provision of basal insulin is simulated in this study. To quantify the performance and robustness of the protocol to errors, namely physiological variability and sensor errors, an in-silico Monte Carlo analysis is performed. Actual patient data from Christchurch Hospital, New Zealand were used as virtual trial patients.
  • Keywords
    Monte Carlo methods; medical control systems; robust control; ICU-HDU transition; TGC protocol; basal insulin; high dependency units; in-silico Monte Carlo analysis; insulin Glargine; model-based control protocol; patient data; physiological variability; robustness analysis; sensor errors; virtual trial patients; Insulin; Monte Carlo methods; Physiology; Plasmas; Protocols; Robustness; Sugar; Monte Carlo; less critical patients; model-based protocol; tight glycaemic control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
  • Conference_Location
    Osaka
  • ISSN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2013.6609473
  • Filename
    6609473