• DocumentCode
    3182853
  • Title

    Study of the Effect of Different Mounted Length of Capillary on Wire Bonding Strength

  • Author

    Yao, Gang ; Han, Lei

  • Author_Institution
    Coll. of the Electromech. Eng., Central South Univ., Changsha
  • fYear
    2007
  • fDate
    26-28 June 2007
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In ultrasonic wire bonding, many factors influence the bonding quality. This article discussed the influence on the bonding quality at different capillary mounted length conditions. Experiment results show that bonding strength, current and voltage will differ at different mounted length of the capillary. The results of this article may be reference for the selection of the capillary mounted length in ultrasonic wire bonding process.
  • Keywords
    integrated circuit packaging; lead bonding; ultrasonic bonding; bonding quality; capillary mounted length conditions; microelectronics industry; packaging level; ultrasonic wire bonding strength; Aluminum; Bonding processes; Data analysis; Educational institutions; Length measurement; Statistics; Torque measurement; Vibrations; Voltage; Wire;