DocumentCode
3182865
Title
Using harmonic distortion determining factor for harmonic evaluation of carrier-based PWM methods
Author
Fukuda, Shoji ; Suzuki, Kunio
Author_Institution
Syst. & Inf. Eng., Hokkaido Univ., Sapporo, Japan
Volume
2
fYear
1997
fDate
5-9 Oct 1997
Firstpage
1534
Abstract
This paper describes the harmonic evaluation of three-phase carrier-based multilevel (2-level to 5-level) PWM inverter methods. The harmonic distortion determining factor (HDDF), which represents the intrinsic spectral property of individual PWM methods, is calculated for each of the multilevel PWM methods, and is used as the common quality index. Almost all the carrier-based PWM schemes that have been proposed so far are considered. HDDF values are helpful for selecting inverter system parameters for AC motor drive applications because they can be used for predicting the current harmonics or torque ripple in AC drives
Keywords
DC-AC power convertors; PWM invertors; harmonic analysis; harmonic distortion; power system harmonics; AC motor drive applications; carrier-based PWM schemes; common quality index; current harmonics; harmonic distortion determining factor; harmonic evaluation; intrinsic spectral property; three-phase multilevel PWM inverters; torque ripple; Harmonic distortion; Inductance; Pulse width modulation; Pulse width modulation inverters; Silicon compounds; Space vector pulse width modulation; Switching frequency; Systems engineering and theory; Torque; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 1997. Thirty-Second IAS Annual Meeting, IAS '97., Conference Record of the 1997 IEEE
Conference_Location
New Orleans, LA
ISSN
0197-2618
Print_ISBN
0-7803-4067-1
Type
conf
DOI
10.1109/IAS.1997.629056
Filename
629056
Link To Document