Abstract :
The fluid flow in the Archimedes pump on dispensing is analyzed. The flow process is divided into three sections: fluid feed path, screw and needle. The three-dimensional model is built, and the flow, when the screw is rotating, is simulated by using Fluent. The effects of rotate velocity, the geometric dimensions of screw, inlet pressure, needle size etc to mass flow rate are described, which provides a theoretical basis for choosing appropriate screw parameters and external conditions.
Keywords :
chip scale packaging; computational fluid dynamics; fasteners; mass transfer; needles; non-Newtonian fluids; pumps; 3D fluid flow; Archimedes pump; Fluent; chip package; dispensing quality; flow process; fluid feed path section; geometric screw dimensions; mass flow rate; needle section; needle size; nonNewtonian fluid; numerical simulations; rotate velocity effects; screw parameters; screw section; Analytical models; Educational institutions; Fasteners; Feeds; Fluid flow; Joining materials; Needles; Numerical simulation; Packaging; Pumps; Archimedes pump; Dispensing quality; Non-Newtonian fluid;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
High Density packaging and Microsystem Integration, 2007. HDP '07. International Symposium on
Conference_Location :
Shanghai
Print_ISBN :
1-4244-1252-8
Electronic_ISBN :
1-4244-1253-6
Type :
conf
DOI :
10.1109/HDP.2007.4283608
Filename :
4283608
Link To Document :
بازگشت