Abstract
A new electron cyclotron emission imaging (ECEI) diagnostic system is implemented on the DIII-D tokamak. This design makes use of technologies successfully demonstrated on the TEXTOR and ASDEX-UG tokamaks, while incorporating new features to provide enhanced flexibility and improved operation. The diagnostic makes use of a dual array configuration, allowing for simultaneous imaging of both the low and high field sides of the plasma, and is fully operational during electron cyclotron resonance heating (ECRH). Additionally, the highly flexible optical design allows for automated remote control of the vertical plasma coverage and resolution, focal plane location, and radial plasma coverage.
Keywords
Tokamak devices; plasma diagnostics; plasma radiofrequency heating; DIII-D tokamak; ECRH; automated remote control; electron cyclotron resonance heating; flexible dual array electron cyclotron emission imaging diagnostic; focal plane location; plasma resolution; radial plasma coverage; vertical plasma coverage; Cyclotrons; Electron emission; Heating; High-resolution imaging; Optical design; Optical imaging; Plasma diagnostics; Resonance; Tokamaks; Variable speed drives; Millimeter wave imaging; cyclotron emission; plasma diagnostics;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference, 2009. APMC 2009. Asia Pacific
Conference_Location
Singapore
Print_ISBN
978-1-4244-2801-4
Electronic_ISBN
978-1-4244-2802-1
Type
conf
DOI
10.1109/APMC.2009.5385324
Filename
5385324
Link To Document