Title :
Detecting aging by-products of SF6 using quadrupole mass spectrometry
Author :
Dervos, Constantine T. ; Papaioannou, Ioanna C. ; Michaelides, Joseph M.
Author_Institution :
Dept. of Electr. & Comput. Eng., Nat. Tech. Univ. of Athens, Greece
Abstract :
Quadrupole mass spectrometry (QMS) has been used to validate the condition of the operating gas in a SF6 GIS 150 kV indoor power substation, running under periodic maintenance for almost 30 years. The switches of the examined system were of the dead tank, single phase, double pressure type. The employed analyzer head enabled detection of positive ions having maximum mass to charge ratio 200 and a minimum detectable concentration 0.5 ppm. According to the experimental results, before the periodic maintenance process the 34S concentration had been increased by a factor of 2 (natural abundance of isotope 34S is 4.5%). Additionally significant amounts of CO 2 could be detected in gas volumes enclosing the current transformers. One month after the periodic maintenance process, i.e. gas dehydration, chamber cleaning and filter substitution, the S isotopic ratios were back to normal and the CO2 concentration was not detectable. In the event of permanent damage of solid insulants (i.e. presence of aluminum fluorides diffused in the epoxy resin) CO2 concentration was still increased at higher concentrations than the CO2 in atmosphere while the dew point measurements did not reveal the weakness. Other SF6 by-products and their concentrations could also be detected with the above measuring instrument (i.e. SF5+, SF4+, SF3+, SF2+, SF+, S+, F+, H2O+, HO+, SOFx+, SO2Fx +) and therefore it may be used as a quality control tool of GIS power plants
Keywords :
SF6 insulation; ageing; current transformers; gas insulated substations; gas insulated switchgear; mass spectroscopic chemical analysis; power transformer insulation; 150 kV; GIS indoor power substation; SF6; aging by-products; current transformers; dead tank type; dew point measurements; double pressure type; isotopic ratios; minimum detectable concentration; operating gas condition; periodic maintenance; positive ions; quadrupole mass spectrometry; quality control tool; single phase switch; solid insulants; Aging; Atmospheric measurements; Cleaning; Current transformers; Gas detectors; Geographic Information Systems; Isotopes; Mass spectroscopy; Substations; Switches;
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1997. IEEE 1997 Annual Report., Conference on
Conference_Location :
Minneapolis, MN
Print_ISBN :
0-7803-3851-0
DOI :
10.1109/CEIDP.1997.641138