Title :
Condition assessment of generator stator insulation by DC ramp and IR tests
Author :
Naranpanawe, W.M.L.B. ; Rathnayake, R.M.H.M. ; Fernando, M.A.R.M. ; Jayantha, G.A.
Author_Institution :
Dept. of Electr. & Electron. Eng., Univ. of Peradeniya, Peradeniya, Sri Lanka
Abstract :
This paper proposes a method of condition assessment of generator stator winding insulation by simultaneously fitting time variation of Insulation Resistance (IR) and DC Ramped voltage plots. The insulation conductivity (σ), permittivity (ε) and response function (f(t)) was used for the assessment. A novel model which derived starting from the frequency domain dielectric response is proposed to model DC Ramp and IR test results. DC ramp, IR and FDS tests were conducted on a non-aged epoxy mica insulated winding sample to verify the proposed model. In a separate laboratory investigation, FDS measurements were conducted on Asphalt-mica and Epoxy-mica insulated winding samples to analyse the parameter variation during artificially ageing and drying. In parallel, DC ramp and IR tests were conducted on field aged windings and their conditions were assessed by the test results and the estimated parameters.
Keywords :
asphalt; electric generators; epoxy insulation; insulation testing; machine insulation; mica; permittivity; stators; DC ramped voltage plots; FDS tests; IR tests; artificial ageing; asphalt-mica; condition assessment method; drying; field aged windings; frequency domain dielectric response; generator stator winding insulation; insulation conductivity; insulation resistance; nonaged epoxy mica insulated winding sample; parameter variation analysis; permittivity; response function; time variation; Aging; Dielectrics; Generators; Insulation; Permittivity; Stator windings; Windings; DC Ramp; Frequency Dielectric Spectroscopy; Insulation Resistance;
Conference_Titel :
Industrial and Information Systems (ICIIS), 2013 8th IEEE International Conference on
Conference_Location :
Peradeniya
Print_ISBN :
978-1-4799-0908-7
DOI :
10.1109/ICIInfS.2013.6731976