Abstract
When we utilize Direct Sampling Mixer (DSM) in multi-standard receivers for channel selection, interference can be caused by signals at odd-times frequencies as the frequency of desired signal. We propose a novel structure of DSM including harmonic rejection with pseudo-sinusoidal pulses and show the measured result of a test-chip we implemented. We achieved about 20dB higher 3rd HRR than that of conventional one.
Keywords
analogue-digital conversion; circuit testing; discrete time systems; harmonics suppression; mixers (circuits); channel selection; harmonic rejection direct sampling mixer; multi-standard receivers; pseudo-sinusoidal pulses; Chromium; Communication standards; Frequency; Interference; Power harmonic filters; Pulse measurements; Receivers; Sampling methods; Software standards; Testing; direct sampling mixer (DSM); discrete-time receiver; harmonic rejection; pseudo-sinusoidal pulse; software-defined radio;