• DocumentCode
    3188081
  • Title

    Design and implementation of a calorimetric measurement facility for determining losses in electrical machines

  • Author

    Szabados, Barna ; Mihalcea, A.

  • Author_Institution
    Power Res. Lab., McMaster Univ., Hamilton, Ont., Canada
  • Volume
    3
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    1785
  • Abstract
    The measurement of the total losses of electrical machines is of most interest to designers for verifying their calculations. These measurements can be done in various ways, however, some lead to more accurate results than others. We will show why the conventional input-output procedure does not result in accurate loss figures, An alternate method is proposed. For this purpose a calorimetric measurement facility was designed and implemented. This paper is intended to present the calibration procedure for this facility, as well as results of tests performed on a 10 hp induction motor
  • Keywords
    calibration; calorimetry; induction motors; loss measurement; machine testing; 10 hp; calibration procedure; calorimetric measurement facility; electrical machines; induction motor; total losses; Calibration; Dielectrics and electrical insulation; Electric machines; Electric variables measurement; Laboratories; Loss measurement; Manufacturing; Power measurement; Temperature dependence; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 2001. IMTC 2001. Proceedings of the 18th IEEE
  • Conference_Location
    Budapest
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-6646-8
  • Type

    conf

  • DOI
    10.1109/IMTC.2001.929507
  • Filename
    929507