• DocumentCode
    3188614
  • Title

    A novel method of measurement of synchronous machine losses using synthetic loading

  • Author

    Soltani, Jafar ; Szabados, Barna

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Isfahan Univ. of Technol., Iran
  • Volume
    3
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    1948
  • Abstract
    Synthetic loading of synchronous machines can be used to test machines for temperature rise and total losses without the need for attaching mechanical load to the shaft. A new phase modulation technique of the voltage is proposed in lieu of the traditional dual frequency method which suffers from cumbersome equipment and also predicts higher losses. A simple bang-bang DC switch is used to modulate the excitation current of an induction generator. System modelling was performed using the traditional 2 axis method, and has proven that the method is feasible. Practical test results are shown to validate the simulated performance. It is shown that the only constraint of this synthetic loading is to maintain the RMS values of the current and voltage at rated values
  • Keywords
    bang-bang control; loss measurement; machine testing; phase modulation; synchronous machines; 2 axis method; RMS values; bang-bang DC switch; dual frequency method; excitation current; induction generator; mechanical load; phase modulation; simulated performance; synchronous machine losses; synthetic loading; system modelling; temperature rise; total losses; Frequency; Joining processes; Loss measurement; Phase modulation; Shafts; Switches; Synchronous machines; Temperature; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 2001. IMTC 2001. Proceedings of the 18th IEEE
  • Conference_Location
    Budapest
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-6646-8
  • Type

    conf

  • DOI
    10.1109/IMTC.2001.929540
  • Filename
    929540