Title :
A novel single compartment in vitro model: Perflurocarbons for electrophysiological studies of the rat urinary bladder
Author :
Choudhary, M.S. ; van Asselt, E. ; van Mastrigt, Ron ; Clavica, F.
Author_Institution :
Dept. of Urology, Erasmus MC, Rotterdam, Netherlands
fYear :
2013
fDate :
3-7 July 2013
Firstpage :
1446
Lastpage :
1449
Abstract :
This study presents a novel single compartment model for in vitro electrophysiological studies of the rat urinary bladder. We tested the functionality and suitability of FC-770 (a Perflurocarbon) for in vitro recording of nerve activity arising from the bladder in a single compartment setup. We have also favorably tested stimulation of the bladder via the bladder nerves in FC-770. The organ viability was monitored by recording spontaneous contractions of the bladder for a certain time. We propose the use of FC-770 as a fluid for nerve recording/stimulation in vitro as well as for maintaining organ viability, over the commonly used two compartmental methods.
Keywords :
bioelectric phenomena; biomechanics; kidney; neurophysiology; organic compounds; patient treatment; physiological models; FC-770; bladder contraction recording; bladder nerve activity recording; bladder nerve stimulation; in vitro electrophysiological study; organ viability monitoring; perflurocarbon; rat urinary bladder; single compartment in vitro model; Bladder; Electrical stimulation; Filling; In vitro; In vivo; Rats;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
Conference_Location :
Osaka
ISSN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2013.6609783
Filename :
6609783