DocumentCode :
3192133
Title :
Mechanical design and fabrication processes for the ALS third-harmonic cavities
Author :
Franks, R.M. ; Hernandez, K. ; Otting, D. ; Henderson, T. ; Plate, D. ; Rimmer, R.A.
Author_Institution :
Lawrence Livermore Nat. Lab., CA, USA
Volume :
2
fYear :
1999
fDate :
1999
Firstpage :
803
Abstract :
It is planned to install five third-harmonic (1.5 GHz) RF cavities in May/June 1999 as an upgrade to the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL). This paper presents mechanical design features, our experiences in using electronic design models to expedite the manufacturing process, and the fabrication processes employed to produce these cavities for the ALS. We discuss some of the “lessons learned” from the PEP-II RF cavity design and fabrication, and outline the improvements incorporated in the new design. We also report observations from our current effort
Keywords :
accelerator RF systems; accelerator cavities; electron accelerators; storage rings; 1.5 GHz; ALS third-harmonic cavities; Advanced Light Source; PEP-II RF cavity design; electron storage ring; electronic design models; fabrication processes; manufacturing process; mechanical design; Computer aided manufacturing; Fabrication; Geometry; Laboratories; Process design; Radio frequency; Shape; Software tools; Solid modeling; Virtual manufacturing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location :
New York, NY
Print_ISBN :
0-7803-5573-3
Type :
conf
DOI :
10.1109/PAC.1999.795361
Filename :
795361