DocumentCode :
3192160
Title :
Detection of EMG-based muscle fatigue during cyclic dynamic contraction using a monopolar configuration
Author :
Hotta, Yoshinobu ; Ito, Kei
Author_Institution :
Niigata Inst. of Technol., Kashiwazaki, Japan
fYear :
2013
fDate :
3-7 July 2013
Firstpage :
2140
Lastpage :
2143
Abstract :
Measurement of surface EMG signals is usually performed using the bipolar (single differential) configuration. However, even if contraction during exercise is performed until near-complete exhaustion, the change in the surface EMG accompanying the fatigue could be undetectable using the bipolar configuration. In order to overcome this disadvantage, this study proposes the measurement of surface EMG using the monopolar configuration. Experimental results show that the monopolar configuration can detect the change in muscle fatigue with greater sensitivity and better stability, as compared to the bipolar configuration.
Keywords :
electromyography; medical signal detection; EMG based muscle fatigue detection; bipolar configuration; cyclic dynamic contraction; exercise; monopolar configuration; near complete exhaustion; single differential configuration; surface EMG signals; Elbow; Electrodes; Electromyography; Fatigue; Indium tin oxide; Muscles; Surface waves;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
Conference_Location :
Osaka
ISSN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2013.6609957
Filename :
6609957
Link To Document :