DocumentCode
3194999
Title
Effects of ac voltage on charge density in a spacer
Author
Elkhodary, S.M. ; Hackam, R.
Author_Institution
Dept. of Electr. Eng., Windsor Univ., Ont., Canada
fYear
1995
fDate
22-25 Oct 1995
Firstpage
500
Lastpage
503
Abstract
The charging of acrylic glass rod under the influence of ac voltage is reported. A linear dependence of the accumulated charge density on the peak ac applied voltage is observed. A comparison between the accumulated charge density with ac and dc applied voltages is reported. The charge densities that accumulate under the effect of ac voltage are smaller than under dc voltage for the same peak voltage level. A switchable dc power supply to simulate an ac voltage application is also employed. Results show that there is an accumulation of both positive and negative charges on the insulator using ac depending on the polarity of the voltage wave
Keywords
flashover; insulation testing; surface charging; surface discharges; AC voltage; accumulated charge density; acrylic glass rod; negative charge accumulation; peak voltage level; positive charge accumulation; voltage wave polarity; Charge measurement; Current measurement; Dielectrics and electrical insulation; Electrodes; Flashover; Glass; Power system reliability; Probes; Steel; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 1995. Annual Report., Conference on
Conference_Location
Virginia Beach, VA
Print_ISBN
0-7803-2931-7
Type
conf
DOI
10.1109/CEIDP.1995.483772
Filename
483772
Link To Document