DocumentCode
3195026
Title
Novel Tune Diagnostics for the Tevatron
Author
Tan, C.Y.
Author_Institution
FNAL, P.O. Box 500, Batavia, IL 60510, USA, cytan@fnal.gov
fYear
2005
fDate
16-20 May 2005
Firstpage
140
Lastpage
144
Abstract
In the Tevatron collider, protons and antiprotons share the same beam pipe. This poses a challenge in the measurement of tunes for both species simultanously because of the possibility of signal contamination from the other species. The tune of each bunch is also very different because of beam-beam effects from parasitic crossing points. This means that the tune diagnostics must be able to differentiate between protons and anti-protons, it also has to measure tunes from each bunch. There are three different tune pickups used in the Tevatron: 1.7 GHz Schottky pickups, 21.4 MHz Schottky pickups and baseband pickups. These devices will be discussed in detail in this paper.
Keywords
Bandwidth; Extraterrestrial measurements; Orbits; Particle beams; Pollution measurement; Protons; RF signals; Radio frequency; Stripline; Switches;