• DocumentCode
    3195064
  • Title

    Lepton Collider Operation with Constant Currents

  • Author

    Wienands, U.

  • Author_Institution
    SLAC, Stanford, CA, USA, uli@slac.stanford.edu
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    149
  • Lastpage
    153
  • Abstract
    Electron-positron colliders have been operating in a top-up-and-coast fashion with a cycle time depending on the beam life time, typically one or more hours. Each top-up involves ramping detector systems in addition to the actual filling time. The loss in accumulated luminosity may be 20-50%. During the last year, both B-Factories have commissioned a continuous-injection mode of operation in which beam is injected without ramping the detector, thus raising luminosity integration by always operating at peak luminosity. Constant beam currents also reduce thermal drift and trips caused by change in beam loading. To achieve this level of operation, special efforts were made to reduce the injection losses and also to implement gating procedures in the detectors, minimizing dead time. Beam collimation can reduce injection noise but also cause an increase in background rates. A challenge can be determining beam lifetime, important to maintain tuning of the beams.
  • Keywords
    Background noise; Colliding beam devices; Collimators; Detectors; Filling; Linear particle accelerator; Noise reduction; Optical modulation; Switches; Thermal loading;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1590385
  • Filename
    1590385