DocumentCode :
3197333
Title :
Eight years of experience with mercury stored ion devices
Author :
Matsakis, D.N. ; Kubik, A.J. ; DeYoung, J.A. ; Giffard, R.P. ; Cutler, L.S.
Author_Institution :
US Naval Obs., Washington, DC, USA
fYear :
1995
fDate :
31 May-2 Jun 1995
Firstpage :
86
Lastpage :
109
Abstract :
The performance of three similar trapped ion frequency standards, which use mercury in a hyperboloidal Paul trap, is presented. Initially, frequency deviations well below 10-14 rms were observed on time scales of 1-10 days, but the standards later underwent frequency variations of up to 10-12 s/s, which are probably due to impurity effects
Keywords :
atomic clocks; frequency measurement; measurement standards; mercury (metal); particle traps; trapped ions; Hg; frequency standards; hyperboloidal Paul trap; impurity effects; mercury stored ion devices; Electromagnetic heating; Electrons; Frequency measurement; Impurities; Laboratories; Measurement standards; Microwave measurements; Observatories; Physics; Resonance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Frequency Control Symposium, 1995. 49th., Proceedings of the 1995 IEEE International
Conference_Location :
San Francisco, CA
Print_ISBN :
0-7803-2500-1
Type :
conf
DOI :
10.1109/FREQ.1995.483888
Filename :
483888
Link To Document :