• DocumentCode
    3197333
  • Title

    Eight years of experience with mercury stored ion devices

  • Author

    Matsakis, D.N. ; Kubik, A.J. ; DeYoung, J.A. ; Giffard, R.P. ; Cutler, L.S.

  • Author_Institution
    US Naval Obs., Washington, DC, USA
  • fYear
    1995
  • fDate
    31 May-2 Jun 1995
  • Firstpage
    86
  • Lastpage
    109
  • Abstract
    The performance of three similar trapped ion frequency standards, which use mercury in a hyperboloidal Paul trap, is presented. Initially, frequency deviations well below 10-14 rms were observed on time scales of 1-10 days, but the standards later underwent frequency variations of up to 10-12 s/s, which are probably due to impurity effects
  • Keywords
    atomic clocks; frequency measurement; measurement standards; mercury (metal); particle traps; trapped ions; Hg; frequency standards; hyperboloidal Paul trap; impurity effects; mercury stored ion devices; Electromagnetic heating; Electrons; Frequency measurement; Impurities; Laboratories; Measurement standards; Microwave measurements; Observatories; Physics; Resonance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Frequency Control Symposium, 1995. 49th., Proceedings of the 1995 IEEE International
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-2500-1
  • Type

    conf

  • DOI
    10.1109/FREQ.1995.483888
  • Filename
    483888