DocumentCode
3197867
Title
Axial RF Power Input into Photocathode Electron Guns
Author
Janssen, D. ; Volkov, V. ; Bluem, H.P. ; Todd, A.M.M.
Author_Institution
FZR, Germany, d.janssen@fz-rossendorf.de
fYear
2005
fDate
16-20 May 2005
Firstpage
743
Lastpage
745
Abstract
The RF power input into an accelerating cavity is usually performed with special couplers that deliver the power in an asymmetric manner. Further, for superconducting cavities, the delivery point is typically into the beam tube beyond the cavity cells. In photocathode electron guns, where the cathode is isolated from the surrounding cavity by a coaxial vacuum gap, another power coupling possibility exists, since the cathode gap forms a coaxial line which can be used for RF power input. In the present paper, we show the advantages of this input coupling method. We then discuss a particular coupler design and present numerical results for normal and superconducting cavities.
Keywords
Acceleration; Cathodes; Coaxial components; Couplers; Electron guns; Heat transfer; Physics; Q factor; Radio frequency; Superconducting transmission lines;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN
0-7803-8859-3
Type
conf
DOI
10.1109/PAC.2005.1590548
Filename
1590548
Link To Document